PX3AG1BH046BSAAX

Honeywell Sensing & Control
Also known as: Foxboro ICTHoneywell Control ProductsHoneywell Micro SwitchHoneywell OptoelectronicsMicro Switch/HoneywellSenSym ICT
Category:  Sensors
Description:  PX3 Series Heavy Duty Pressure Transducer, sealed gage, 0 bar to 46 bar, 4.75 V to 5.25 V input, ratiometric: 5.0 Vdc to 4.5  ...show more
Avg. Price  $97.26 |  Auth QOH  43 |  Ind QOH  38
Part Status:  Active
Lead Time:  6 week(s)
Distributor Disti# RoHS Status Pkg. Stock (as of) Price
A
DigiKey480-6719-NDROHS3 CompliantBox19
1
$38.94
5
$35.872
BUY
2266-PX3AG1BH046BSAAX-NDROHS3 CompliantBulk8
1
$117.01
4
$114.85
BUY
A
Master ElectronicsCompliant8
1
$280.68
10
$280.68
BUY
A
Onlinecomponents.comCompliant8
1
$284.96
10
$280.68
BUY
A
Steven EngineeringPX3AG1BH046BSAAXInquire
BUY
ComSIT Distribution GmbH10
BUY
Electro SonicYes8
1
$293.509
10
$289.1
BUY
Farnell25322215
1
$81.21
BUY
44193267
1
$126.96
BUY
Verical an Arrow Division80009920CompliantIn Stock1
1
$109.72
4
$107.7
BUY
30746159CompliantIn Stock7
1
$109.72
4
$107.7
BUY
Detailed information:
  • Pressure range: 1 bar to 50 bar | 15 psi to 700 psi (absolute and sealed gage)
  • Ratiometric output: 0.5 Vdc to 4.5 Vdc or 0.33 Vdc to 2.97 Vdc
  • Fully calibrated and temperature compensated
  • Total Error Band: ±1.0 %FSS from -20°C to 85°C [-4°F to 185°F]
  • External freeze/thaw resistance: 6 cycles from -30°C to 50°C [-22°F to 122°F]
  • Insulation resistance: >100 MOhm, 1500 Vdc (in dry, non-ionized air)
  • Dielectric strength: AC1500V, 1 min. or AC1800V, 1 s (in dry, non-ionized air)
  • Current consumption: 3.5 mA max.
  • EMC (radiated immunity): 200 V/m per ISO 11452-2
  • Ingress protection IP67 (Metri-Pack 150), IP69K (cable harness)
  • Response time: <2 ms
  • RoHS, REACH, and CE compliant
  • Six industry-standard pressure port types, including a tube port which provides for hermetically-sealed process connection
  • Industrial: Refrigerant pressure monitoring in HVAC/R systems; air compressor system pressure
  • Transportation: Air system monitoring; hydraulic oil pressure monitoring

    The PX3 Series is not recommended for use with media involving water, saturated air such as steam and vapor, and ammonia.