PX2AN1XX100PAAAX

Honeywell Sensing & Control
Also known as: Foxboro ICTHoneywell Control ProductsHoneywell Micro SwitchHoneywell OptoelectronicsMicro Switch/HoneywellSenSym ICT
Category:  Sensors
Description:  PX2 Series Heavy Duty Pressure Transducer, absolute, 0 psi to 100 psi, 4.75 V to 5.25 V input, ratiometric: 5.0 Vdc 10 %Vs t  ...show more
Avg. Price  $314.74 |  Auth QOH  92 |  Ind QOH  85
Part Status:  Active
Lead Time:  6 week(s)
Distributor Disti# RoHS Status Pkg. Stock (as of) Price
A
DigiKey480-3840-NDRoHS CompliantBulk18
1
$168.84
BUY
A
Master ElectronicsCompliant37
1
$511.63
10
$511.63
BUY
A
Onlinecomponents.comCompliant37
1
$519.42
10
$511.63
BUY
A
Steven EngineeringPX2AN1XX100PAAAXInquire
BUY
Electro SonicYes37
1
$535.003
10
$526.979
BUY
Verical an Arrow Division87359271Not CompliantIn Stock13
1
$48.2029
BUY
52467037Not CompliantIn Stock35
1
$727.188
10
$716.282
BUY
Detailed information:
  • Pressure range: 1 bar to 70 bar | 100 kPa to 7 MPa | 15 psi to 1000 psi
  • Pressure reference: Absolute, sealed gage or vented gage
  • Pressure port types: 7/16-20 UNF 1/4 in 45° Flare Female Schrader (SAE J512), 7/16-20 UNF 45° Flare Male (SAE J513), 7/16-20 UNF 37° Flare Male (SAE J514), G1/4 (ISO 1179-3), G1/8 (ISO 1179-3), M12 x 1.5 (ISO 6149-3), 1/4-18 NPT, 1/8-27 NPT, 9/16-18 UNF, (SAE J1926-3), or 7/16-20 UNF (SAE J1926-3)
  • Electrical connector types: Metri-Pack 150 (UL 94 HB or V-0 options), Micro M12, DIN, Deutsch, or cable harness (1 m, 2 m, 3 m, or 5 m)
  • Total Error Band: ±2.0 %
  • Operating and compensated temperature range: -40°C to 125°C [-40°F to 257°F]
  • Response time: <2 ms
  • Life: Minimum of 10 million cycles to operating pressure
  • Output transfer function: Ratiometric, regulated or current
  • Mechanical shock rating: 100 G per MIL-STD-202F, Method 213B, Cond. F
  • Vibration rating: 20 G sweep, 10 Hz to 2000 Hz
  • Ingress protection: Up to IP69K
  • Radiated immunity protection: Up to 100 V/m (ISO 11452-2)
  • Flame retardant options: UL 94 HB standard on all electrical terminations; UL 94 V-0 available upon request
  • Industrial: Refrigerant pressure monitoring in HVAC/R systems; air compressor system pressure
  • Transportation: Air system monitoring; hydraulic oil pressure monitoring

    The PX2 Series is not recommended for use with media involving water, saturated air such as steam and vapor, and ammonia.